Abstract:
The Lab-on-a-chip systems regarding the terrorist activity for the detection of warfare agents and explosives are discussed. These systems have the potential to provide reliable forensic information in a faster, simpler and cheaper manner. These systems integrate all of the stages in analysis, such as sample preparation, chemical reactions, separation and detection on the single substrate. In the design and construction of a basic Lab-on-a-chip system, consideration has to be given to the method of fluidic control, choice of detection principle, fabrication protocol and method of packaging.
Type:
Article
Language:
en
Keywords:
Lab-on-a-chip; terrorism; detection; explosives
ISSN:
0020-2940
Rights:
No publisher policy information on http://www.sherpa.ac.uk/romeo/ [Accessed 05/05/2010]
Citation Count:
2 [Scopus, 05/05/2010]

Full metadata record

DC FieldValue Language
dc.contributor.authorAli, Z. (Zulfiqur)en
dc.date.accessioned2010-05-05T14:08:41Z-
dc.date.available2010-05-05T14:08:41Z-
dc.date.issued2005-04-
dc.identifier.citationMeasurement and Control; 38(3):87-91en
dc.identifier.issn0020-2940-
dc.identifier.urihttp://hdl.handle.net/10149/97980-
dc.description.abstractThe Lab-on-a-chip systems regarding the terrorist activity for the detection of warfare agents and explosives are discussed. These systems have the potential to provide reliable forensic information in a faster, simpler and cheaper manner. These systems integrate all of the stages in analysis, such as sample preparation, chemical reactions, separation and detection on the single substrate. In the design and construction of a basic Lab-on-a-chip system, consideration has to be given to the method of fluidic control, choice of detection principle, fabrication protocol and method of packaging.en
dc.language.isoenen
dc.publisherInstitute of Measurement & Controlen
dc.rightsNo publisher policy information on http://www.sherpa.ac.uk/romeo/ [Accessed 05/05/2010]en
dc.subjectLab-on-a-chipen
dc.subjectterrorismen
dc.subjectdetectionen
dc.subjectexplosivesen
dc.titleLab-on-a-chip for terrorist weapons managementen
dc.typeArticleen
dc.contributor.departmentUniversity of Teesside. School of Science and Technology.en
dc.identifier.journalMeasurement and Controlen
ref.citationcount2 [Scopus, 05/05/2010]en
or.citation.harvardAli, Z. (2005) 'Lab-on-a-chip for terrorist weapons management', Measurement and Control, 38 (3), pp.87-91.-
All Items in TeesRep are protected by copyright, with all rights reserved, unless otherwise indicated.